1、N5K & Cat3750

较新版本的NX-OS在N5K上支持1G或10G,但N5K不支持auto-speed sensing

如下是故障信息的体现:3750和N5K之间安装GLC-SX-MM模块并连接,在3750上看了相关状态,出现了这个错误:

Description: Gi1/1/1: This port has been disabled because Non Compliant  Gigabit Interface Converter (GBIC) connector detected.

(此端口已被禁用,因为检测到非兼容千兆位接口转换器(GBIC)连接器。)

Recommendation: Replace connector with cisco compliant Gigabit Interface Converter (GBIC) connector. Refer switch technical documentation to determine cisco compliant connector. Enable the port again.

使用符合cisco标准的千兆位接口转换器(GBIC)连接器替换连接器。 请参阅交换机技术文档以确定符合cisco的连接器。 再次启用端口。

 

操作如下

①两个设备都支持GLC-SX-MM

②尝试shu/no shu接口

③Cat3750上体现的log:

*Apr  16 01:48:41.190: %PHY-4-SFP_NOT_SUPPORTED: The SFP in Gi1/1/1 is not supported
*Apr  16 01:48:41.190: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/1/1, putting Gi1/1/1 in err-disable state

④查看接口(支持GLC-SX-MM,接口下显示信息也OK)

3750_sw1#sh int gig 1/1/1 capa
GigabitEthernet1/1/1
  Model:                 WS-C3750X-48P
  Type:                  1000BaseSX SFP
  Speed:                 1000
  Duplex:                full
  Trunk encap. type:     802.1Q,ISL
  Trunk mode:            on,off,desirable,nonegotiate
  Channel:               yes
  Broadcast suppression: percentage(0-100)
  Flowcontrol:           rx-(off,on,desired),tx-(none)
  Fast Start:            yes
  QoS scheduling:        rx-(not configurable on per port basis),
                         tx-(4q3t) (3t: Two configurable values and one fixed.)
  CoS rewrite:           yes
  ToS rewrite:           yes
  UDLD:                  yes
  Inline power:          no
  SPAN:                  source/destination
  PortSecure:            yes

  Dot1x:                 yes
3750_sw1#

⑤但是3750的状态是not connect

3750_sw1#sh int gig 1/1/1 status

Port      Name               Status       Vlan       Duplex  Speed Type
Gi1/1/1                      notconnect   1            auto   auto 1000BaseSX SFP
3750_sw1#

⑥查看N5K上接口状态和信息:

N5K1# sh int e1/5 status

--------------------------------------------------------------------------------
Port          Name               Status    Vlan      Duplex  Speed   Type
--------------------------------------------------------------------------------
Eth1/5        --                 sfpInvali 1         full    10G     SFP-1000BAS
N5K1#
N5K1# sh int e1/5 capa
Ethernet1/5
  Model:                 N5K-C5548UP-SUP
  Type (SFP capable):    10Gbase-(unknown)
  Speed:                 1000,10000
  Duplex:                full
  Trunk encap. type:     802.1Q
  Channel:               yes
  Broadcast suppression: no
  Flowcontrol:           rx-(off/on),tx-(off/on)
  Rate mode:             none
  QOS scheduling:        rx-(6q1t),tx-(1p6q0t)
  CoS rewrite:           no
  ToS rewrite:           no
  SPAN:                  yes
  UDLD:                  yes
  Link Debounce:         yes
  Link Debounce Time:    yes
  MDIX:                  no
  Pvlan Trunk capable:   yes
  TDR capable:           no
  FabricPath capable:    yes
  Port mode:             Switched
  FEX Fabric:            yes

N5K1#

其实这里应该看到N5K和Cat3750之间的speed不匹配。

⑦查看N5K的log

N5K1#sh log | inc 1/5
...
2019 Apr 6 18:10:26 N5K1 %ETHPORT-5-IF_DOWN_NONE: Interface Ethernet1/5 is down (None)
...
2019 Apr 6 19:06:10 N5K1 %ETHPORT-5-IF_HARDWARE: Interface Ethernet1/5, hardware type changed to No-Transceiver

⑧在N5K手动设置速度

N5K1# sh int e1/5 stat

--------------------------------------------------------------------------------
Port          Name               Status    Vlan      Duplex  Speed   Type
--------------------------------------------------------------------------------
Eth1/5        --                 connected 1         full    1000     SFP-1000BAS
N5K1#

可以看到修改后正常了。

Summary: The newer versions of NX-OS support 1G or 10G on the N5K, but the N5K is not auto-speed sensing. If you run into something similar, even error messages on the remote device, check the port speed on the N5K.

 

2、N5600 & FEX 2248PQ 

 

标签:no,No,Nexus,3750,changed,SFP,N5K,N5K1,yes
来源: https://www.cnblogs.com/MomentsLee/p/11247706.html

本站声明: 1. iCode9 技术分享网(下文简称本站)提供的所有内容,仅供技术学习、探讨和分享;
2. 关于本站的所有留言、评论、转载及引用,纯属内容发起人的个人观点,与本站观点和立场无关;
3. 关于本站的所有言论和文字,纯属内容发起人的个人观点,与本站观点和立场无关;
4. 本站文章均是网友提供,不完全保证技术分享内容的完整性、准确性、时效性、风险性和版权归属;如您发现该文章侵犯了您的权益,可联系我们第一时间进行删除;
5. 本站为非盈利性的个人网站,所有内容不会用来进行牟利,也不会利用任何形式的广告来间接获益,纯粹是为了广大技术爱好者提供技术内容和技术思想的分享性交流网站。

专注分享技术,共同学习,共同进步。侵权联系[81616952@qq.com]

Copyright (C)ICode9.com, All Rights Reserved.

ICode9版权所有