ICode9

精准搜索请尝试: 精确搜索
首页 > 其他分享> 文章详细

IfcStructuralLoadTemperature

2021-07-07 18:31:21  阅读:215  来源: 互联网

标签:temperature positive uniform member IfcThermodynamicTemperatureMeasure IfcStruct


IfcStructuralLoadTemperature

修改记录

ItemSPFXMLChangeDescription
IFC2x3 to IFC4
    IfcStructuralLoadTemperature        
      DeltaTConstant   X MODIFIED Name changed from DeltaT_Constant to DeltaTConstant.
      DeltaTY   X MODIFIED Name changed from DeltaT_Y to DeltaTY.
      DeltaTZ   X MODIFIED Name changed from DeltaT_Z to DeltaTZ.

 

 

 

 

 

 

 

 

实体IfcStructuralLoadTemperature的实例应用于定义由温度变化引起的响应。如下图所示,温度的变化用一个应用于整个截面的恒定值和截面外部纤维之间的温差值来表示。

IFC2x2中增加的新实体。

 

 

 

 

 

Attribute inheritance

#AttributeTypeCardinalityDescriptionC
IfcStructuralLoad
1 Name IfcLabel [0:1] Optionally defines a name for this load. X
IfcStructuralLoadOrResult
IfcStructuralLoadStatic
IfcStructuralLoadTemperature
2 DeltaTConstant IfcThermodynamicTemperatureMeasure [0:1] Temperature change which affects the complete section of the structural member, or the uniform portion of a non-uniform temperature change.
NOTE  A positive value describes an increase in temperature. I.e. a positive constant temperature change causes elongation of a member, or compression in the member if there are respective restraints.
X
3 DeltaTY IfcThermodynamicTemperatureMeasure [0:1] Non-uniform temperature change, specified as the difference of the temperature change at the outer fibre of the positive y direction minus the temperature change at the outer fibre of the negative y direction of the analysis member.
NOTE  A positive non-uniform temperature change in y induces a negative curvature of the member about z, or a positive bending moment about z if there are respective restraints. y and z are local member axes.
X
4 DeltaTZ IfcThermodynamicTemperatureMeasure [0:1] Non-uniform temperature change, specified as the difference of the temperature change at the outer fibre of the positive z direction minus the temperature change at the outer fibre of the negative z direction of the analysis member.
NOTE  A positive non-uniform temperature change in z induces a positive curvature of the member about y, or a negative bending moment about y if there are respective restraints. y and z are local member axes.
X
 

 

EXPRESS Specification

ENTITY IfcStructuralLoadTemperature
 SUBTYPE OF (IfcStructuralLoadStatic);
  DeltaTConstant : OPTIONAL IfcThermodynamicTemperatureMeasure;
  DeltaTY : OPTIONAL IfcThermodynamicTemperatureMeasure;
  DeltaTZ : OPTIONAL IfcThermodynamicTemperatureMeasure;
END_ENTITY;

 

 

#########################

标签:temperature,positive,uniform,member,IfcThermodynamicTemperatureMeasure,IfcStruct
来源: https://www.cnblogs.com/herd/p/14982934.html

本站声明: 1. iCode9 技术分享网(下文简称本站)提供的所有内容,仅供技术学习、探讨和分享;
2. 关于本站的所有留言、评论、转载及引用,纯属内容发起人的个人观点,与本站观点和立场无关;
3. 关于本站的所有言论和文字,纯属内容发起人的个人观点,与本站观点和立场无关;
4. 本站文章均是网友提供,不完全保证技术分享内容的完整性、准确性、时效性、风险性和版权归属;如您发现该文章侵犯了您的权益,可联系我们第一时间进行删除;
5. 本站为非盈利性的个人网站,所有内容不会用来进行牟利,也不会利用任何形式的广告来间接获益,纯粹是为了广大技术爱好者提供技术内容和技术思想的分享性交流网站。

专注分享技术,共同学习,共同进步。侵权联系[81616952@qq.com]

Copyright (C)ICode9.com, All Rights Reserved.

ICode9版权所有